MultiPlus-II 12/3000 - 120-50 - 2x 120V UL Approved
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A).
It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload occurs. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the critical component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual.
Uninterrupted AC Power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Remote Monitoring & Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1374.96 |
|
|
Quattro-II - 12/3000 - 120-50/50 - 2X 120V
Similar to the MultiPlus-II 2x120V, the Quattro-II 2x120V is a combined inverter and charger specifically designed for standard North American 50A 120/240VAC split-phase applications. Additionally, it can accept two AC inputs and automatically connect to the active source.
120/240V Input and Output, or 120V Input and Output (Always 120V Output When in Inverter Mode)
The two AC inputs can be supplied from a split-phase 120/240V source or a single-phase 120V source. When one of the AC sources is available, the Quattro will feed through the AC to its output. The output will therefore mirror the AC input.
The inverter/charger connects to the neutral and the preferred input line (L1). The power needed to charge the batteries will therefore be drawn from L1.
The Quattro switches to inverter operation when no AC source is available. The inverter output is 120V single-phase. In invert mode, the Quattro connects both output lines (L1 and L2) together to provide 120VAC to loads on either line.
Any 240V loads will therefore be supplied only when the Quattro is supplied by a split-phase AC source. This prevents heavy loads such as water heaters or 240V air conditioners from discharging the battery.
PowerControl and PowerAssist - Boosting the Capacity of the Grid or a Generator
A maximum grid or generator current can be set. The Quattro will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is often required only for a limited period, the Quattro will compensate for insufficient generator, shore, or grid power with power from the battery. When the load reduces, the spare power is used to recharge the battery (available on L1 input only).
Two AC Inputs and Two AC Outputs
The Quattro can be connected to two independent AC sources, for example,shore-side power and a generator, or two generators. The Quattro-II will automatically connect to the active source.
The main output has no-break functionality. The Quattro takes over the supply to the connected 120V loads in the event of a grid failure or when shore/generator power is disconnected. The transfer time of the L1 output is less than 18 milliseconds, so computers and other electronic equipment will continue to operate without disruption. The transfer time of the L2 output is longer: approximately 40 milliseconds.
The second (auxiliary) output is live only when AC is available on the input of the Quattro. Loads that should not discharge the battery can be connected to this output.
Virtually Unlimited Power Thanks to Parallel and Three-Phase Operation
Up to 6 Quattros can operate in parallel to achieve a higher power output. In addition to parallel connections, three units of the same model can be configured for three-phase output. In multi-phase setups, L2 is disabled on all units.
On-Site System Configuring, Monitoring and Control
Settings can be changed in a matter of minutes with the VictronConnect app or VEConfigure software (computer or laptop and MK3-USB interface are needed). Several monitoring and control options are available: Cerbo GX, Color Control GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, and Digital Multi Control Panel.
Remote Configuration and Monitoring
Install a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed.
Specifications:
PowerControl & PowerAssist: Yes (on L1 input)
Transfer Switch: 50 A
Maximum AC Input Current: 50A (each leg)
Inverter Specifications:
DC Input Voltage Range: 9.5-17V
Output When in Inverter Mode: Output voltage: 120 Vac ± 2% / Frequency: 60 Hz ± 0.1% (1)
Cont. Output Power at 25°C: 3000 VA
Cont. Output Power at 25°C: 2400 W
Cont. Output Power at 40°C: 2200 W
Cont. Output Power at 65°C: 1700 W
Maximum Apparent Feed-in Power: 2500 VA
Peak Power: 5500 W
Maximum Efficiency: 93%
Zero Load Power: 15W
Zero Load Power in AES Mode: 10W
Zero Load Power in Search Mode: 4W
Charger Specifications:
AC Input: Split-phase: 180-280Vac 45 – 65Hz / Single-phase: 90-140Vac 45 – 65Hz
Charge Voltage 'Absorption': 14.4V
Charge Voltage 'Float': 13.8V
Storage Mode: 13.2V
Maximum Battery Charge Current: 120A
Battery Temperature Sensor: Yes
General Specifications:
Auxiliary Output: 50 A (each leg)
External AC current Sensor (optional): 100A
Programmable Relay: Yes
Protection: a – g
VE.Bus Communication Port: For parallel and three-phase operation, remote monitoring and system integration
General Purpose com. Port: Yes, 2x
Remote On-Off: Yes
Operating Temperature Range: -40 to +65°C (-40 -150°F) Fan assisted cooling
Humidity (non-condensing): Max 95%
Enclosure Specifications:
Material & Color: Steel, blue RAL 5012
Protection Category: IP22
Battery-Connection: 2x2 M8 bolts
120/240 V AC-Connection: Screw terminals 21 mm² (4 AWG)
Weight: 32.8 kg / (52 lb)
Dimensions (hxwxd): 579 x 319 x 168 mm / (23 x 13 x 7 inch)
Standards:
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Can be adjusted to 50 Hz
Protection key: Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 120Vac on inverter output, input voltage ripple too high
Non-linear load, crest factor 3:1.
Up to 75-degrees F / 25-degrees C ambient temperature
Switches off when no external AC source is available.
Programmable Relay That Can for Example Be Set for General Alarm or DC under Voltage or Genset Start/Stop Function: AC rating: 120Vac / 4A / DC rating: 4A up to 35dc, 1A up to 60Vdc
Use, for example, to communicate with a lithium battery BMS
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1652.40 |
|
|
MultiPlus-II 12/3000 - 120-50 - 120V - UL Approved
MultiPlus-II 48/3000 - 35-50 - 120V - UL ApprovedThe MultiPlus-II, an inverter/charger, combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). It also has all the features of the MultiGrid with built-in anti-islanding and increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters.
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will operate without disruption.
Remote Monitoring and Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backup generator and more.
Specifications:
PowerControl & PowerAssist: Yes
Transfer Switch: 50A
Maximum AC Input Current: 50A
Inverter Specifications:
DC Input Voltage Range: 9,5 – 17 V
Output: Output Voltage 120 VAC ± 2% / Frequency 60 Hz ± 0,1% (1)
Continuous Output Power at 25°C (3): 3000 VA
Continuous Output Power at 25°C: 2400 W
Continuous Output Power at 40°C: 2200 W
Continuous Output Power at 65°C: 1700 W
Maximum Apparent Feed-In Power: 2500 VA
Peak Power: 5500 W
Maximum Efficiency: 93%
Zero Load Power: 13 W
Zero Load Power in AES Mode: 9 W
Zero Load Power in Search Mode: 3 W
Charger Specifications:
AC Input: Input Voltage Range 90-140 VAC / Input Frequency: 45 – 65 Hz
Charge Voltage 'Absorption': 14,4 V
Charge Voltage 'Float': 13,8 V
Storage Mode: 13,2 V
Maximum Battery Charge Current (4): 120 A
Battery Temperature Sensor: Yes
General Specifications:
Auxiliary Output: Yes (32 A)
External AC Current Sensor (optional): 100 A
Programmable Relay (5): Yes
Protection (2): a – g
VE.Bus Communication Port: For parallel, split phase and three phase operation, remote monitoring and system integration
General Purpose Com. Port: Yes, 2x
Remote On-Off: Yes
Operating Temperature Range: -40 to +65°C (-40 – 150 °F) (fan assisted cooling)
Humidity (Non-Condensing): Max 95%
Enclosure Specifications:
Material & Color: Steel, blue RAL 5012
Protection Category: IP22
Battery-Connection: M8 bolts
120 V AC-Connection: Screw terminals 13 mm² (6 AWG)
Weight: 9 kg
Dimensions (hxwxd) (mm): 578 x 277 x 148
Standards:
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, UL458
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
*Note: For a short period of time this product was called MultiGrid-II.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1207.68 |
|
|
MultiPlus-II 12/3000 - 120-50 - 120V
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A).
It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload occurs. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the critical component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual.
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Remote Monitoring and Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1196.46 |
|
|
Quattro-II - 24/3000 - 70-50/50 - 2X 120V
Similar to the MultiPlus-II 2x120V, the Quattro-II 2x120V is a combined inverter and charger specifically designed for standard North American 50A 120/240VAC split-phase applications. Additionally, it can accept two AC inputs and automatically connect to the active source.
120/240V Input and Output, or 120V Input and Output (Always 120V Output When in Inverter Mode)
The two AC inputs can be supplied from a split-phase 120/240V source or a single-phase 120V source. When one of the AC sources is available, the Quattro will feed through the AC to its output. The output will therefore mirror the AC input.
The inverter/charger connects to the neutral and the preferred input line (L1). The power needed to charge the batteries will therefore be drawn from L1.
The Quattro switches to inverter operation when no AC source is available. The inverter output is 120V single-phase. In invert mode, the Quattro connects both output lines (L1 and L2) together to provide 120VAC to loads on either line.
Any 240V loads will therefore be supplied only when the Quattro is supplied by a split-phase AC source. This prevents heavy loads such as water heaters or 240V air conditioners from discharging the battery.
PowerControl and PowerAssist - Boosting the Capacity of the Grid or a Generator
A maximum grid or generator current can be set. The Quattro will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is often required only for a limited period, the Quattro will compensate for insufficient generator, shore, or grid power with power from the battery. When the load reduces, the spare power is used to recharge the battery (available on L1 input only).
Two AC Inputs and Two AC Outputs
The Quattro can be connected to two independent AC sources, for example,shore-side power and a generator, or two generators. The Quattro-II will automatically connect to the active source.
The main output has no-break functionality. The Quattro takes over the supply to the connected 120V loads in the event of a grid failure or when shore/generator power is disconnected. The transfer time of the L1 output is less than 18 milliseconds, so computers and other electronic equipment will continue to operate without disruption. The transfer time of the L2 output is longer: approximately 40 milliseconds.
The second (auxiliary) output is live only when AC is available on the input of the Quattro. Loads that should not discharge the battery can be connected to this output.
Virtually Unlimited Power Thanks to Parallel and Three-Phase Operation
Up to 6 Quattros can operate in parallel to achieve a higher power output. In addition to parallel connections, three units of the same model can be configured for three-phase output. In multi-phase setups, L2 is disabled on all units.
On-Site System Configuring, Monitoring and Control
Settings can be changed in a matter of minutes with the VictronConnect app or VEConfigure software (computer or laptop and MK3-USB interface are needed). Several monitoring and control options are available: Cerbo GX, Color Control GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, and Digital Multi Control Panel.
Remote Configuration and Monitoring
Install a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed.
Specifications:
PowerControl & PowerAssist: Yes (on L1 input)
Transfer Switch: 50 A
Maximum AC Input Current: 50A (each leg)
Inverter Specifications:
DC Input Voltage Range: 19-33V
Output When in Inverter Mode: Output voltage: 120 Vac ± 2% / Frequency: 60 Hz ± 0.1% (1)
Cont. Output Power at 25°C: 3000 VA
Cont. Output Power at 25°C: 2400 W
Cont. Output Power at 40°C: 2200 W
Cont. Output Power at 65°C: 1700 W
Maximum Apparent Feed-in Power: 2500 VA
Peak Power: 5500 W
Maximum Efficiency: 94%
Zero Load Power: 11W
Zero Load Power in AES Mode: 8W
Zero Load Power in Search Mode: 4W
Charger Specifications:
AC Input: Split-phase: 180-280Vac 45 – 65Hz / Single-phase: 90-140Vac 45 – 65Hz
Charge Voltage 'Absorption': 28.8 V
Charge Voltage 'Float': 27.6 V
Storage Mode: 26.4 V
Maximum Battery Charge Current: 70 A
Battery Temperature Sensor: Yes
General Specifications:
Auxiliary Output: 50 A (each leg)
External AC current Sensor (optional): 100A
Programmable Relay: Yes
Protection: a – g
VE.Bus Communication Port: For parallel and three-phase operation, remote monitoring and system integration
General Purpose com. Port: Yes, 2x
Remote On-Off: Yes
Operating Temperature Range: -40 to +65°C (-40 -150°F) Fan assisted cooling
Humidity (non-condensing): Max 95%
Enclosure Specifications:
Material & Color: Steel, blue RAL 5012
Protection Category: IP22
Battery-Connection: 2 M8 bolts
120/240 V AC-Connection: Screw terminals 21 mm² (4 AWG)
Weight: 22.5 kg / (50lb)
Dimensions (hxwxd): 579 x 319 x 168 mm / (23 x 13 x 7 inch)
Standards:
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Can be adjusted to 50 Hz
Protection key: Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 120Vac on inverter output, input voltage ripple too high
Non-linear load, crest factor 3:1.
Up to 75-degrees F / 25-degrees C ambient temperature
Switches off when no external AC source is available.
Programmable Relay That Can for Example Be Set for General Alarm or DC under Voltage or Genset Start/Stop Function: AC rating: 120Vac / 4A / DC rating: 4A up to 35dc, 1A up to 60Vdc
Use, for example, to communicate with a lithium battery BMS
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1652.40 |
|
|
MultiPlus-II 12/3000 120-50 2X 120V
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A).
It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shore side supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual.
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Remote Monitoring and Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more.
Specifications:
PowerControl & PowerAssist: Yes
Transfer Switch: 50A
Maximum AC Input Current: 50A (each leg)
Inverter Specifications:
DC Input Voltage Range: 9,5 – 17 V
Output: Output Voltage 120 VAC ± 2% / Frequency 60 Hz ± 0,1% (1)
Continuous Output Power at 25°C (3): 3000 VA
Continuous Output Power at 25°C: 2400 W
Continuous Output Power at 40°C: 2200 W
Continuous Output Power at 65°C: 1700 W
Maximum Apparent Feed-In Power: 2500 VA
Peak Power: 5500 W
Maximum Efficiency: 93%
Zero Load Power: 13W
Zero Load Power in AES Mode: 15W
Zero Load Power in Search Mode: 4W
Charger Specifications:
AC Input (Split Phase): 180-280 VAC 45 – 65 Hz
AC Input (Single Phase): 90-140 VAC 45 – 65 Hz
Charge Voltage 'Absorption': 14,4 V
Charge Voltage 'Float': 13,8 V
Storage Mode: 13,2 V
Maximum Battery Charge Current (4): 120 A
Battery Temperature Sensor: Yes
General Specifications:
Auxiliary Output: 35 A Each leg
External AC Current Sensor (optional): 100 A
Programmable Relay (5): Yes
Protection (2): a – g
VE.Bus Communication Port: For parallel, split phase and three phase operation, remote monitoring and system integration
General Purpose Com. Port: Yes, 2x
Remote On-Off: Yes
Operating Temperature Range: -40 to +65°C (-40 – 150 °F) (fan assisted cooling)
Humidity (Non-Condensing): Max 95%
Enclosure Specifications:
Material & Color: Steel, blue RAL 5012
Protection Category: IP22
Battery-Connection: 2x2 M8 bolts
120 V AC-Connection: Screw terminals 21 mm² (4 AWG)
Weight: 22 kg
Dimensions (hxwxd) (mm): 578 x 275 x 148
Standards:
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29,
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
*Note: For a short period of time this product was called MultiGrid-II.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1360.68 |
|
|
MultiPlus 12/3000 - 120-50 - 230V - VE.Bus
The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, and multiple system integration features.
Two AC Outputs
The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater, for example, can be connected to this output (a second output is available on models rated at 3 kVA and more).
Virtually Unlimited Power Thanks to Parallel Operation
Up to 6 Multis can operate in parallel to achieve a higher power output. Six 24/5000/120 units, for example, will provide 25 kW / 30 kVA output power with 720 AMP charging capacity.
Three Phase Capability
In addition to parallel connections, three units of the same model can be configured for three-phase output. But that’s not all up to 6 sets of three units can be connected in parallel for a 75 kW / 90 kVA inverter and more than 2000 Amp charging capacity.
PowerControl - Dealing with Limited Generator, Shore Side or Grid Power
The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shoreside supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel, a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist - Boosting the capacity of shore or generator power
This feature takes the principle of PowerControl to a further dimension. It allows MultiPlus to supplement the capacity of the alternative source. Where peak power is often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces the spare power is used to recharge the battery.
Solar energy: AC Power is Available Even During a Grid Failure
The MultiPlus can be used in off-grid as well as grid-connected PV and other alternative energy systems. Loss of mains detection software is available.
System Configuring:
In the case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure
Parallel and three-phase applications can be configured with VE.Bus Quick Configure and VE.Bus System Configurator software
Off-grid, grid-interactive, and self-consumption applications, involving grid-tie inverters and/or MPPT Solar Chargers can be configured with Assistants (dedicated software for specific applications)
On-site Monitoring and Control
Several options are available: Battery Monitor, Multi Control Panel, Color control for GX or other GX devices, smartphone, tablet (Bluetooth Smart), laptop, or computer (USB or RS232).
Remote Monitoring and Control
Color Control GX or other GX devices. Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
Remote Configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed, and settings can be changed remotely
Specifications:
PowerControl: Yes
PowerAssist: Yes
Transfer Switch (A): 16 or 50
Inverter Specifications:
Input Voltage Range (V DC): 9,5 – 17 V 19 – 33 V 38 – 66 V
Output: Output voltage: 230 VAC, ± 2% / Frequency 50 Hz ± 0,1%
Continuous Output Power at 25°C (VA): 3000
Continuous Output Power at 25°C (W): 2400
Continuous Output Power at 40°C (W): 2200
Continuous Output Power at 65°C (W): 1700
Peak Power (W): 6000
Maximum Efficiency (%): 93 / 94 / 95
Zero Load Power (W): 20 / 20 / 25
Zero Load Power in AES Mode (W): 15 / 15 / 20
Zero Load Power in Search Mode (W): 8 / 10 / 12
Charger Specifications:
AC Input: Input voltage range: 187-265 VAC / Input frequency: 45 – 65 Hz / Power factor: 1
Charge Voltage Absorption (V DC): 14,4 / 28,8 / 57,6
Charge Voltage Float (V DC): 13,8 / 27,6 / 55,2
Storage Mode (V DC): 13,2 / 26,4 / 52,8
Charge Current House Battery (A): 120 / 70 / 35
Charge Current Starter Battery (A): 4 (12 V and 24 V models only)
Battery Temperature Sensor: Yes
General Specifications:
Auxiliary Output: Yes (16A)
Programmable Relay: Yes
Protection: a - g
VE.Bus Communication Port: For parallel and three-phase operation, remote monitoring, and system integration
General purpose com. Port: Yes
Remote On-Off: Yes
Common Characteristics: Operating temp. range: -40 to +65°C (fan-assisted cooling) / Humidity (non-condensing): max 95%
Enclosure Specifications:
Common Characteristics: Material & Color: aluminum (blue RAL 5012) / Protection category: IP 21
Battery-Connection: Four M8 bolts (2 plus and 2 minus connections)
230 V AC-Connection: Screw terminals 13mm^2 (6 AWG) M6 bolts
Weight (kg): 18
Dimensions (hxwxd in mm): 362 x 258 x 218
Standards
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road Vehicles: 12V and 24V models: ECE R10-4
Anti-Islanding: See Victron's website
Can be adjusted to 60 HZ. 120 V models available on request
Protection Key: Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 VAC on the inverter output, input voltage ripple is too high
Non-linear load, crest factor 3:1
Up to 25°C ambient
Switches off when no external AC source is available
Programmable Relay That Can, Among Other Things, Be Set for General Alarm Including DC Undervoltage or genset start/stop function / AC rating: 230 V/4A / DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC / A.o. to communicate with a lithium-ion battery BMS
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1703.40 |
|
|
MultiPlus-II 48/3000 35-50 120V
The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external current sensor option which extends the PowerControl and PowerAssist function to 100A.
PowerControl and PowerAssist - Boosting the Capacity of the Grid or a Generator
A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.When the load reduces, the spare power is used to recharge the battery.
Solar Energy: AC Power Available Even During a Grid Failure
The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is compatible with both solar charger controllers and grid-tie inverters.
Two AC Outputs
The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the battery, like a water heater for example, can be connected to this output.
Virtually Unlimited Power Thanks to Parallel, Split Phase and Three Phase Operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/3000/35 units, for example, will provide 15 kW / 18 kVA output power with 210 Amps charging capacity.
In addition to parallel connection, two units of the same model can be connected for a 240V split phase output, and three units of the same model can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel connected per phase.
On-Site System Configuring, Monitoring and Control
Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface needed).
Several monitoring and control options are available: Color Control GX, Venus GX, Octo GX, CANvu GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote Configuring and Monitoring
Install a Color Control GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed.
Specifications:
PowerControl & PowerAssist: Yes
Transfer Switch: 50A
Maximum AC Input Current: 50A
Inverter Specifications:
DC Input Voltage Range: 38 -66 V
Output: Output Voltage 120 VAC ± 2% / Frequency 60 Hz ± 0,1% (1)
Continuous Output Power at 25°C (3): 3000 VA
Continuous Output Power at 25°C: 2400 W
Continuous Output Power at 40°C: 2200 W
Continuous Output Power at 65°C: 1700 W
Peak Power: 5500 W
Maximum Efficiency: 95%
Zero Load Power: 11 W
Zero Load Power in AES Mode: 7 W
Zero Load Power in Search Mode: 2 W
Charger Specifications:
AC Input: Input Voltage Range 90-140 VAC / Input Frequency: 45 – 65 Hz
Charge Voltage 'Absorption': 57,6 V
Charge Voltage 'Float': 55,2 V
Storage Mode: 52,8 V
Maximum Battery Charge Current: 35 A
Battery Temperature Sensor: Yes
General Specifications:
Auxiliary Output: 32 A
External AC Current Sensor (optional): 100 A
Programmable Relay: Yes
Protection: a – g
VE.Bus Communication Port: For parallel, split phase and three phase operation, remote monitoring and system integration
General Purpose Com. Port: Yes, 2x
Remote On-Off: Yes
Operating Temperature Range: -40 to +65°C (-40 – 150 °F) (fan assisted cooling)
Humidity (Non-Condensing): Max 95%
Enclosure Specifications:
Material & Color: Steel, blue RAL 5012
Protection Category: IP22
Battery-Connection: M8 bolts
120 V AC-Connection: Screw terminals 13 mm² (6 AWG)
Weight: 19 kg / 42 lb.
Dimensions (hxwxd): (mm) 572 x 277 x 147 / (inch) 22.5” x 10.9” x 5.8”
Standards:
Listings: UL1741 pending
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, CSA 22.2 107.1-16
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, EC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
*Note: For a short period of time this product was called MultiGrid-II
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1402.50 |
|
|
MultiPlus-II 48/3000 - 35-50 - 120V - UL Approved
The MultiPlus-II, an inverter/charger, combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). It also has all the features of the MultiGrid with built-in anti-islanding and increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters.
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will operate without disruption.
Remote Monitoring and Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backup generator and more.
Specifications:
PowerControl & PowerAssist: Yes
Transfer Switch: 50A
Maximum AC Input Current: 50A
Inverter Specifications:
DC Input Voltage Range: 38 – 66 V
Output: Output Voltage 120 VAC ± 2% / Frequency 60 Hz ± 0,1% (1)
Continuous Output Power at 25°C (3): 3000 VA
Continuous Output Power at 25°C: 2400 W
Continuous Output Power at 40°C: 2200 W
Continuous Output Power at 65°C: 1700 W
Maximum Apparent Feed-In Power: 2500 VA
Peak Power: 5500 W
Maximum Efficiency: 95%
Zero Load Power: 11 W
Zero Load Power in AES Mode: 7 W
Zero Load Power in Search Mode: 2 W
Charger Specifications:
AC Input: Input Voltage Range 90-140 VAC / Input Frequency: 45 – 65 Hz
Charge Voltage 'Absorption': 57,6 V
Charge Voltage 'Float': 55,2 V
Storage Mode: 52,8 V
Maximum Battery Charge Current (4): 35 A
Battery Temperature Sensor: Yes
General Specifications:
Auxiliary Output: Yes (32 A)
External AC Current Sensor (optional): 100 A
Programmable Relay (5): Yes
Protection (2): a – g
VE.Bus Communication Port: For parallel, split phase and three phase operation, remote monitoring and system integration
General Purpose Com. Port: Yes, 2x
Remote On-Off: Yes
Operating Temperature Range: -40 to +65°C (-40 – 150 °F) (fan assisted cooling)
Humidity (Non-Condensing): Max 95%
Enclosure Specifications:
Material & Color: Steel, blue RAL 5012
Protection Category: IP22
Battery-Connection: M8 bolts
120 V AC-Connection: Screw terminals 13 mm² (6 AWG)
Weight: 9 kg
Dimensions (hxwxd) (mm): 536 x 275 x 147
Standards:
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, UL458
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
*Note: For a short period of time this product was called MultiGrid-II.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1421.88 |
|
|
MultiPlus-II 24/3000 - 70-50 - 120V - UL Approved
The MultiPlus-II, an inverter/charger, combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). It also has all the features of the MultiGrid with built-in anti-islanding and increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters.
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will operate without disruption.
Remote Monitoring and Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backup generator and more.
Specifications:
PowerControl & PowerAssist: Yes
Transfer Switch: 50A
Maximum AC Input Current: 50A
Inverter Specifications:
DC Input Voltage Range: 19–33 V
Output: Output Voltage 120 VAC ± 2% / Frequency 60 Hz ± 0,1% (1)
Continuous Output Power at 25°C (3): 3000 VA
Continuous Output Power at 25°C: 2400 W
Continuous Output Power at 40°C: 2200 W
Continuous Output Power at 65°C: 1700 W
Maximum Apparent Feed-In Power: 2500 VA
Peak Power: 5500 W
Maximum Efficiency: 94%
Zero Load Power: 13 W
Zero Load Power in AES Mode: 9 W
Zero Load Power in Search Mode: 3 W
Charger Specifications:
AC Input: Input Voltage Range 90-140 VAC / Input Frequency: 45 – 65 Hz
Charge Voltage 'Absorption': 28,8 V
Charge Voltage 'Float': 27,6 V
Storage Mode: 26,4 V
Maximum Battery Charge Current (4): 70 A
Battery Temperature Sensor: Yes
General Specifications:
Auxiliary Output: Yes (32 A)
External AC Current Sensor (optional): 100 A
Programmable Relay (5): Yes
Protection (2): a – g
VE.Bus Communication Port: For parallel, split phase and three phase operation, remote monitoring and system integration
General Purpose Com. Port: Yes, 2x
Remote On-Off: Yes
Operating Temperature Range: -40 to +65°C (-40 – 150 °F) (fan assisted cooling)
Humidity (Non-Condensing): Max 95%
Enclosure Specifications:
Material & Color: Steel, blue RAL 5012
Protection Category: IP22
Battery-Connection: M8 bolts
120 V AC-Connection: Screw terminals 13 mm² (6 AWG)
Weight: 9 kg
Dimensions (hxwxd) (mm): 536 x 277 x 147
Standards:
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, UL458
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
*Note: For a short period of time this product was called MultiGrid-II.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1207.68 |
|
|
MultiPlus-II 12/3000 - 120-50 - 120V
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A).
It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload occurs. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the critical component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual.
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Remote Monitoring and Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more.
Please contact your dealer for any returns, repairs, or support issues related to this product.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1420.86 |
|
|
MultiPlus-II 24/3000 - 70-50 - 2x120V
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A).
It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters.
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Remote Monitoring & Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backupgenerator and more…"
Note: for a short period of time this product was called MultiGrid-II.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1360.68 |
|
|
MultiPlus-II 24/3000 - 70-50 - 120V
The MultiPlus-II combines the functions of the MultiPlus and the MultiGrid. It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A).
It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.
PowerAssist
The MultiPlus-II will prevent the overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload occurs. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
ESS: Energy Storage Systems
The MultiPlus-II is the critical component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual.
Uninterrupted AC Power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Remote Monitoring & Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop, or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto-starting a backup generator and more.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1196.46 |
|
|
Quattro 48/10000/140-100/100 - 230V - +50A Aux VE.Bus
The Victron Energy Quattro Inverter/Charger has 2 AC inputs with an integrated transfer switch, 2 AC Outputs, a unique PowerAssist feature, and virtually unlimited power thanks to parallel operation. Models range from 3kVA to 15kVA per module.
Similar to the MultiPlus, the Quattro is also a combined inverter and charger. Additionally, it can accept two AC inputs and automatically connect to the active source. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology plus multiple systems integration features such as three or split-phase operation and parallel operation.
Two AC inputs with integrated transfer switch
The Victron Energy Quattro can be connected to two independent AC sources, for example, shore-side power and a generator, or two generators. The Quattro will automatically connect to the active source.
Two AC Outputs
The main output has no-break functionality. In the event of a grid failure, or shore or generator power being disconnected, the Victron Quattro takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on one of the inputs of the Quattro. Loads that should not discharge the battery, such as air-conditioning or a water heater can be connected to this output.
Unique PowerAssist feature
The Victron Energy Quattro will prevent the overload of a limited AC source. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery.
Virtually unlimited power thanks to parallel operation
Up to 6 Victron Quattros can operate in parallel to achieve higher power output. Three-phase or split phase operation is also possible.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
3584.79 |
|
|
MultiPlus 12/1200 - 50-16 - 120V - VE. Bus
The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the MultiPlus has several advanced features, as outlined below.
Parallel Operation and Three-Phase Capability
Up to six Multis can operate in parallel to achieve higher power output. In addition to parallel connection, three units can be configured for three-phase output.
PowerControl - Dealing with Limited Generator, Shore Side or Grid Power
With the Multi Control Panel, a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.
PowerAssist - Boosting the Capacity of Shore or Generator Power
This feature takes the principle of PowerControl to a further dimension. It allows MultiPlus to supplement the capacity of the alternative source. Where peak power is often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load is reduced, the spare power is used to recharge the battery.
Four Stage Adaptive Charger and Dual-Bank Battery Charging
The main output provides a powerful charge to the battery system using advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Charger datasheet and Victron's website under Technical Information. In addition to this, the MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.
High Start-Up Power
It is needed to start high-inrush loads such as power converters for LED lamps, halogen lamps, or electric tools.
Search Mode
When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode, the Multi, when operating in inverter mode, is switched off in case of no load or very low load and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.
Programmable Relay
By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energize in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low).
Remote On/Off/Charger On
Three pole connector.
On-Site System Configuring, Monitoring, and Control
After installation, the MultiPlus is ready to go. Some settings can be changed with DIP switches. 500/800/1200VA models: remote switch/battery charge voltage/inverter frequency/search mode. 1600/2000VA models: battery charge voltage/search mode. For more settings use VE-Config or the VE. Bus Smart dongle.
Remote Configuring and Monitoring
Install a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on Victron's VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed.
Specifications:
PowerControl: Yes
PowerAssist: Yes
Transfer Switch (A): 16
Inverter Specifications:
Input Voltage Range (V DC): 9,5 – 17 V, 19 – 33 V, 38– 66 V
Output voltage: 230 VAC, ± 2% / Frequency 50 Hz ± 0,1%
Continuous Output Power at 25°C (VA): 1200
Continuous Output Power at 25°C (W): 1000
Continuous Output Power at 40°C (W): 900
Continuous Output Power at 65°C (W): 600
Peak Power (W): 2400
Maximum Efficiency (%): 93 / 94 / 95%
Zero Load Power (W): 10 / 9 / 10 W
Zero Load Power in Search Mode (W): 3 / 3 / 3 W
Charger Specifications:
AC Input: Input voltage range: 187-265 VAC / Input frequency: 45 – 65 Hz
Charge Voltage Absorption (V DC): 14,4 / 28,8 / 57,6
Charge Voltage Float (V DC): 13,8 / 27,6
Storage Mode (V DC): 13,8 / 27,6 / 55,2
Charge Current House Battery (A): 50 / 25 / 13 A
Charge Current Starter Battery (A): 1A (12 V and 24 V models only)
Battery Temperature Sensor: Yes
General Specifications:
Programmable Relay: Yes (1x)
Protection: a - g
VE.Bus Communication Port: For parallel and three-phase operation, remote monitoring and system integration (RJ45-splitter ASS030065510 needed for 500 / 800 / 1200 VA models)
Remote On-Off: On/off/charger only
DIP Switches: Yes
Internal DC Fuse: 200 / 100 / 50 A
Operating Temperature Range: -40 - +65°C / -40 to 150°F (fan-assisted cooling), Humidity (non-condensing) max 95%
Enclosure Specifications:
Common Characteristics: Material & Color: aluminum (blue RAL 5012) / Protection category: IP 21
Battery-Connection: 35 / 25 / 10 mm²
230 V AC-Connection: G-ST18i connector
Weight: 8.2 kg
Dimensions (H x W x D): 406 x 250 x 100 mm / 15.98 x 9.84 x 3.94 in.
Standards:
Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Automotive Directive: ECE R10-5
Can be adjusted to 60Hz and 240V
Protection: Output short circuit, Overload, Battery voltage too high, Battery voltage too low, Temperature too high, 230VAC on inverter output, Input voltage ripple too high
Non-linear load, crest factor 3:1
Up to 25°C ambient
A programmable relay that can be set for General alarm, DC under voltage or generator start/stop signal function, AC rating: 230V/4A, DC rating: 4A up to 35VDC, 1A up to 60VDC
Remote/battery charge voltage/inverter frequency/search mode
Battery charge voltage/search mode
Please contact your dealer for any returns, repairs or support issues related to this product.
|
584.46 |
|