Lynx Power-In Class-T M10 Terminals
The Lynx Class-T Power In connects and fuses up to two strings of lithium batteries. It features a positive and negative busbar, connections for two Class-T fuses, and a connection to ground the DC system. The Class T-fuses, are available in 225A, 250A, 350A, and 400A (must be purchased separately).
For installations using three or more strings of lithium batteries, use multiple Lynx Class-T modules. As a core component of the Lynx Distribution system, the Lynx Class-T seamlessly integrates with all other M10 Lynx products.
The Lynx Distribution System
The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, and battery monitoring and/or lithium battery management.
The Lynx Distribution System Consists of the Following Parts
Lynx Power In
A positive and negative busbar with four batteries or DC equipment connections.
Lynx Distributor
A positive and negative busbar with four fused connections for batteries or DC equipment and fuse monitoring is available in two versions.
Lynx Shunt VE.Can
A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
Lynx Smart BMS
For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring.
It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal. Available as a 1000A model with M10 busbars.
Specifications
Power:
Voltage Range: 9 - 60Vdc
Current Rating: 1000Adc continuous
Connections: M10
Busbar: 3/8”
Physical:
Enclosure Material: ABS
Enclosure Dimensions (H x W x D): 279 x 169 x 97mm
Unit Weight: 2.1 kg
Busbar Material: Tinned copper
Busbar Dimensions (H x W): 8 x 30mm
Environmental:
Operating Temperature Range: -40°C to +60°
Storage Temperature Range: -40°C to +60°
Humidity: Max. 95% (non-condensing)
Protection Class: IP20
Please contact your dealer for any returns, repairs or support issues related to this product.
|
204.00 |
|
|
Lynx Power-In with M10 Terminals
The Lynx Power In contains a positive and negative busbar with 4 connections for batteries, loads, or chargers and a ground connection. It is part of the Lynx Distribution System. This version is a M10 busbar.
Note that M10 refers to the busbar connection joints where the modules are connected. The fuse and cable connections are always M8.
The Lynx Distribution System
The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, and battery monitoring and/or lithium battery management.
The Lynx Distribution System Consists of the Following Parts
Lynx Power In
A positive and negative busbar with four batteries or DC equipment connections.
Lynx Distributor
A positive and negative busbar with four fused connections for batteries or DC equipment and fuse monitoring, is available in two versions.
Lynx Shunt VE.Can
A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
Lynx Smart BMS
For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring.
It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal. Available as a 1000A model with M10 busbars.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
193.80 |
|
|
Lynx Power-In
The lynx power in module is used to connect batteries via an external fuse. It can be useful if you have multiple parallel strings. Due to the extremely high short circuit current potential of most battery banks, it is suggested to use an external fuse system with an appropriate fault current interruption rating (such as an NH HRC).
The Power In contains a negative and positive DC bus-bar with M8 bolts in which to connect batteries cables. It can take cables up to 22 mm in diameter through the bottom entry guides, and no limit via the two side connections.
Warranty Info
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
169.32 |
|
|
Lynx Distributor with M10 Terminals
The Lynx Distributor contains a positive and a negative busbar. The positive busbar has four fuse-protected connections with fuse monitoring. The negative busbar has four connections and a ground connection. This model is part of the Lynx distribution and is a M10 busbar model. Note that M10 refers to the busbar connection joints where the modules are connected. The fuse and cable connections are always M8.
The Lynx Distributor has a power LED and four fuse status indication LEDs. If connected to a Lynx Smart BMS, up to 4 Lynx Distributors can send fuse status information to the Lynx Smart BMS. This feature is not available when connected to a Lynx Shunt VE.Can.
Features:
1000A model with M10 busbars
The Lynx Distributor ships together with a 40cm RJ10 cable, which provides power to the Lynx Distributor and is also used to transmit data if connected to a Lynx Smart BMS
The Lynx Distributor is designed to hold MEGA fuses
If the Lynx Distributor is connected to a Lynx Smart BMS, it can be monitored and set up with the VictronConnect App
Up to 4 connected Lynx distributors can be monitored with a GX device if connected to a Lynx Smart BMS
The Lynx Distribution System
The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, and battery monitoring and/or lithium battery management.
The Lynx Distribution System Consists of the Following Parts
Lynx Power In
A positive and negative busbar with four batteries or DC equipment connections.
Lynx Distributor
A positive and negative busbar with four fused connections for batteries or DC equipment and fuse monitoring, is available in two versions.
Lynx Shunt VE.Can
A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
Lynx Smart BMS
For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring.
It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal. Available as a 1000A model with M10 busbars.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
266.22 |
|
|
Class T Fuse Holder with 2 Additional Studs 225-400A
Providing high-capacity fusing, fast response and very high interrupt ratings (ANL up to 6,000 Amps, Class-T up to 20,000 Amps), these fuse holders are ideal for protecting today's demanding onboard power electronics technology including inverters and battery chargers. They also protect wiring from short circuits. Pro Installer fuse holders' durable construction allow fuses to run at maximum load.
Radiused ends improve cable routing options
Class-T: 225-400 Amp
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
50.47 |
|
|
Class T Fuse Holder with 2 Additional Studs 450-600A
Providing high-capacity fusing, fast response and very high interrupt ratings (ANL up to 6,000 Amps, Class-T up to 20,000 Amps), these fuse holders are ideal for protecting today's demanding onboard power electronics technology including inverters and battery chargers. They also protect wiring from short circuits. Pro Installer fuse holders' durable construction allow fuses to run at maximum load.
Radiused ends improve cable routing options
Class-T: 450-600 Amp
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
59.23 |
|
|
5117 225AMP Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5118 250AMP Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5119 300AMP Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5120 350AMP Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5121 400AMP Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5112 110A Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5113 125A Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5114 150A Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5115 Fuse A3T (Class T) 175A
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|