Applications for the 809-BR-HS 12V Magnetic Drive Pump include hot water systems and solar heating.
March Pump's industrial 809-BR-HS 12V & 24V is an American seal-less centrifugal magnetic drive pump ideal for applications such as hot water systems. It is capable of generating a maximum flow of 6 gallons per minute at 2.5 feet, and its maximum head is 15.5 Feet (or around 6.5PSI). The standard wet end (the materials that come into contact with the solution) is composed of Bronze, Stainless Steel, Teflon, Silicone and Ryton/Teflon/Glass. The inlet connection is 0.5 inch male pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 0.04 Horsepower DC Brush Type Motor, available in 12 or 24 Volts. The 12 Volt motor has an operating range from 0 to 14 Volts, and the 24 Volt motor has an operating range from 0 to 26 Volts. The maximum internal pressure the pump can tolerate is 150PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Max Flow
6 GPM
22.7 LPM
Max Head
15.5 FT
4.7 M
Power
.04 HP
.029 KW
Electrical
12V Range 0-14 or 24V Range 0-26
Type
Centrifugal Mag Drive
Inlet
1/2"MPT
Outlet
1/2"MPT
Wet End
Bronze (Front Housing), Stainless Steel (Rear Housing, Shaft), Teflon (Thrust Washer), Silicone (O-Ring), Ryton/Teflon/Glass (Impeller)
|
526.73 |
|
|
March 809 815 Series Mag-Drive Centrifugal Pumps
The March MAGNE-BOOST Hydronic hot water booster pumps are a non-self priming unit built to handle liquid transfer in heating and cooling operations. Typical applications include home heating systems, solar heating systems, heat recovery systems and recirculating water in domestic and commercial hot water tanks. These pumps are not food rated.
• Brewery pump - the March 809 and 815 series of pumps are commonly used by Home Brewers and Breweries.
• Maximum liquid temperature for the 809 and 815 series is 250 F.
• Port configurations include in-line and center inlet with side discharge.
• Construction materials: Bronze, Stainless Steel, Ryton/Polysulfil Plastic. Impellers are Teflon plastic.
• There are many motor options available Including AC, DC and High Speed versions for added flow.
March Pump Mag-Drive Centrifugal Pump Bronze with Base 24VDC High Speed 7.5GPM 1/2"MPT Ports
|
498.00 |
|
|
March 809-BR-HS 12V Mag Drive Pump
Applications for the 809-BR-HS 12V Magnetic Drive Pump include hot water systems and solar heating.
March Pump's industrial 809-BR-HS 12V & 24V is an American seal-less centrifugal magnetic drive pump ideal for applications such as hot water systems. It is capable of generating a maximum flow of 6 gallons per minute at 2.5 feet, and its maximum head is 15.5 Feet (or around 6.5PSI). The standard wet end (the materials that come into contact with the solution) is composed of Bronze, Stainless Steel, Teflon, Silicone and Ryton/Teflon/Glass. The inlet connection is 0.5 inch male pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 0.04 Horsepower DC Brush Type Motor, available in 12 or 24 Volts. The 12 Volt motor has an operating range from 0 to 14 Volts, and the 24 Volt motor has an operating range from 0 to 26 Volts. The maximum internal pressure the pump can tolerate is 150PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Max Flow
6 GPM
22.7 LPM
Max Head
15.5 FT
4.7 M
Power
.04 HP
.029 KW
Electrical
12V Range 0-14 or 24V Range 0-26
Type
Centrifugal Mag Drive
Inlet
1/2"MPT
Outlet
1/2"MPT
Wet End
Bronze (Front Housing), Stainless Steel (Rear Housing, Shaft), Teflon (Thrust Washer), Silicone (O-Ring), Ryton/Teflon/Glass (Impeller)
|
465.08 |
|
|
Applications for the 809-BR-HS Magnetic Drive Pump include hot water systems and solar heating.
March Pump's industrial 809-BR-HS is an American seal-less centrifugal magnetic drive pump ideal for applications such as hot water systems. It is capable of generating a maximum flow of 6 gallons per minute at 2 feet, and its maximum head is 12 Feet (or around 5PSI). The standard wet end (the materials that come into contact with the solution) is composed of Bronze, Stainless Steel, Teflon, Silicone and Ryton/Teflon/Glass. The inlet connection is 0.5 male pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.04 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 150PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Unit System 60Hz 50Hz Max Flow
6 GPM
18.9 LPM
Max Head
12.1 FT
2.5 M
Power
.04 HP
.029 KW
Electrical
115V 50/60HZ or 230V 50/60HZ
Type
Centrifugal Mag Drive
Inlet
1/2"MPT
Outlet
1/2"MPT
Wet End
Bronze (Front Housing), Stainless Steel (Rear Housing, Shaft), Teflon (Thrust Washer), Silicone (O-Ring), Ryton/Teflon/Glass (Impeller)
|
408.53 |
|
|
March 809 BR HS Mag-Drive Centrifugal Pump Bronze 24V Pump
The March MAGNE-BOOST Hydronic hot water booster pumps are a non-self priming unit built to handle liquid transfer in heating and cooling operations. Typical applications include home heating systems, solar heating systems, heat recovery systems and recirculating water in domestic and commercial hot water tanks. These pumps are not food rated.
• Brewery pump - the March 809 and 815 series of pumps are commonly used by Home Brewers and Breweries.
• Maximum liquid temperature for the 809 and 815 series is 250 F.
• Port configurations include in-line and center inlet with side discharge.
• Construction materials: Bronze, Stainless Steel, Ryton/Polysulfil Plastic. Impellers are Teflon plastic.
• There are many motor options available Including AC, DC and High Speed versions for added flow.
March Pump Mag-Drive Centrifugal Pump Bronze 24VDC High Speed 7.5GPM 1/2"MPT Ports
|
463.13 |
|
|
March 815 Series Mag-Drive Centrifugal Pumps
The March MAGNE-BOOST Hydronic hot water booster pumps are a non-self priming unit built to handle liquid transfer in heating and cooling operations. Typical applications include home heating systems, solar heating systems, heat recovery systems and recirculating water in domestic and commercial hot water tanks. These pumps are not food rated.
• Brewery pump - the March 809 and 815 series of pumps are commonly used by Home Brewers and Breweries.
• Maximum liquid temperature for the 809 and 815 series is 250 F.
• Port configurations include in-line and center inlet with side discharge.
• Construction materials: Bronze, Stainless Steel, Ryton/Polysulfil Plastic. Impellers are Teflon plastic.
• There are many motor options available Including AC, DC and High Speed versions for added flow.
March Pump Mag-Drive Centrifugal Pump Bronze 230V High Speed 7.2GPM 1/2"MPT Ports
|
428.03 |
|
|
March 0125-0141-0100 Marine Pump LC-2M-MD
March Pump’s industrial LC-2M-MD is an American submersible seal-less centrifugal magnetic drive pump. It is capable of generating a maximum flow of 5 gallons per minute at 1 foot, and its maximum head is 13 Feet (5.5PSI). The LC-2M-MD pump may be used submerged or not submerged. The pump is Ignition Protected per SAE J1171 and ISO 8846. It is capable of 12,000 BTU a hour.
Max Flow: 5 GPM
Max Head: 13 FT
Power: 0.02 HP
Electrical/Air: 115V 50/60Hz
115V Motor
6 Foot Cord, Submersible
60Hz: 1Ph 0.2HP/0.015kW, 0.92 AMPS, 3450RPM
50Hz: 1Ph 0.18HP/0.014kW, 1.1 AMPS, 2850RPM
Inlet: 3/8"FPT & 3/4"MPT
Outlet: 1/4"MPT
Submersible: Yes
Wet End: Polypropylene (Front Housing, Impeller), Nylon (Rear Housing) Viton (O-Ring), Buna N (O-Ring, Cooling Tube Seal), 316 Stainless Steel (Shaft, Cooling Tube), Ceramic (Thrust Washer), Ceramic Magnet
Uses: Submersible or Open Air
When submerged, the following is also in contact with the solution: Epoxy, Buna N, Cord
Max Internal Pressure: 25 PSI / 1.7 bar
Max Internal Temperature: 130 °F / 54 °C
Ignition Protected per SAE J1171 and ISO 8846: Rated IP67
|
294.84 |
|
|
March 0125-0142-0100 Marine Pump LC-2M-MD
March Pump’s industrial LC-2M-MD is an American submersible seal-less centrifugal magnetic drive pump. It is capable of generating a maximum flow of 5 gallons per minute at 1 foot, and its maximum head is 13 Feet (5.5PSI). The LC-2M-MD pump may be used submerged or not submerged. The pump is Ignition Protected per SAE J1171 and ISO 8846. It is capable of 12,000 BTU a hour.
Max Flow: 18.5 LPM
Max Head: 2.7 M
Power: 0.014 KW
Electrical/Air: 230V 50/60Hz
230V Motor
6 Foot Cord, Submersible
60Hz: 1Ph 0.025HP/0.019kW, 0.53 AMPS, 3450RPM
50Hz: 1Ph 0.18HP/0.014kW, 0.72 AMPS, 2850RPM
Inlet: 3/8"FPT & 3/4"MPT
Outlet: 1/4"MPT
Submersible: Yes
Wet End: Polypropylene (Front Housing, Impeller), Nylon (Rear Housing) Viton (O-Ring), Buna N (O-Ring, Cooling Tube Seal), 316 Stainless Steel (Shaft, Cooling Tube), Ceramic (Thrust Washer), Ceramic Magnet
Uses: Submersible or Open Air
When submerged, the following is also in contact with the solution: Epoxy, Buna N, Cord
Max Internal Pressure: 25 PSI / 1.7 bar
Max Internal Temperature: 130 °F / 54 °C
Ignition Protected per SAE J1171 and ISO 8846: Rated IP67
|
321.75 |
|
|
March 809-BR 24V Mag Drive Pump
Applications for the 809-BR 12V & 24V Magnetic Drive Pump include hot water systems, refrigeration systems and solar heating.
March Pump's industrial 809-BR 12V & 24V is an American seal-less centrifugal magnetic drive pump ideal for applications such as hot water systems. It is capable of generating a maximum flow of 5 gallons per minute at 1.5 feet, and its maximum head is 7 Feet (or around 3PSI). The standard wet end (the materials that come into contact with the solution) is composed of Bronze, Stainless Steel, Teflon, Silicone and Ryton/Teflon/Glass. The inlet connection is 0.5 male pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 0.01 Horsepower DC Brush Type Motor, available in 12 or 24 Volts. The 12 Volt motor has an operating range from 0 to 14 Volts, and the 24 Volt motor has an operating range from 0 to 26 Volts. The maximum internal pressure the pump can tolerate is 150PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Max Flow
5 GPM
18.9 LPM
Max Head
7.1 FT
2.1 M
Power
.01 HP
.007 KW
Electrical
12V Range 0-14 or 24V Range 0-26
Type
Centrifugal Mag Drive
Inlet
1/2"MPT
Outlet
1/2"MPT
Wet End
Bronze (Front Housing), Stainless Steel (Rear Housing, Shaft), Teflon (Thrust Washer), Silicone (O-Ring), Ryton/Teflon/Glass (Impeller)
|
465.08 |
|
|
March 809 BR 12VDC
Applications for the 809-BR 12V & 24V Magnetic Drive Pump include hot water systems, refrigeration systems and solar heating.
March Pump's industrial 809-BR 12V & 24V is an American seal-less centrifugal magnetic drive pump ideal for applications such as hot water systems. It is capable of generating a maximum flow of 5 gallons per minute at 1.5 feet, and its maximum head is 7 Feet (or around 3PSI). The standard wet end (the materials that come into contact with the solution) is composed of Bronze, Stainless Steel, Teflon, Silicone and Ryton/Teflon/Glass. The inlet connection is 0.5 male pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 0.01 Horsepower DC Brush Type Motor, available in 12 or 24 Volts. The 12 Volt motor has an operating range from 0 to 14 Volts, and the 24 Volt motor has an operating range from 0 to 26 Volts. The maximum internal pressure the pump can tolerate is 150PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Max Flow
5 GPM
18.9 LPM
Max Head
7.1 FT
2.1 M
Power
.01 HP
.007 KW
Electrical
12V Range 0-14 or 24V Range 0-26
|
459.23 |
|
|
Applications for the 809-BR Magnetic Drive Pump include hot water systems and solar heating.
March Pump's industrial 809-BR is an American seal-less centrifugal magnetic drive pump ideal for applications such as hot water systems. It is capable of generating a maximum flow of 4.5 gallons per minute at 0.5 feet, and its maximum head is 4.3 Feet (or around 1.8PSI). The standard wet end (the materials that come into contact with the solution) is composed of Bronze, Stainless Steel, Teflon, Silicone and Ryton/Teflon/Glass. The inlet connection is 0.5 male pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.01 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 150PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Unit System 60Hz 50Hz Max Flow
4.5 GPM
10.3 LPM
Max Head
4.3 FT
.92 M
Power
.01 HP
.007 KW
Electrical
115V 50/60HZ or 230V 50/60HZ
Type
Centrifugal Mag Drive
Inlet
1/2"MPT
Outlet
1/2"MPT
Wet End
Bronze (Front Housing), Stainless Steel (Rear Housing, Shaft), Teflon (Thrust Washer), Silicone (O-Ring), Ryton/Teflon/Glass (Impeller)
|
380.25 |
|
|
Applications for the 809-BR Magnetic Drive Pump include hot water systems and solar heating.
March Pump's industrial 809-BR is an American seal-less centrifugal magnetic drive pump ideal for applications such as hot water systems. It is capable of generating a maximum flow of 4.5 gallons per minute at 0.5 feet, and its maximum head is 4.3 Feet (or around 1.8PSI). The standard wet end (the materials that come into contact with the solution) is composed of Bronze, Stainless Steel, Teflon, Silicone and Ryton/Teflon/Glass. The inlet connection is 0.5 male pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.01 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 150PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Unit System 60Hz 50Hz Max Flow
4.5 GPM
10.3 LPM
Max Head
4.3 FT
.92 M
Power
.01 HP
.007 KW
Electrical
115V 50/60HZ or 230V 50/60HZ
Type
Centrifugal Mag Drive
Inlet
1/2"MPT
Outlet
1/2"MPT
Wet End
Bronze (Front Housing), Stainless Steel (Rear Housing, Shaft), Teflon (Thrust Washer), Silicone (O-Ring), Ryton/Teflon/Glass (Impeller)
|
403.65 |
|
|
March 809 BRC HS 12VDC Mag-Drive Pump
March Mag-Drive Centrifugal Pumps Bronze 12VDC High Speed 5.5GPM
The March MAGNE-BOOST Hydronic hot water booster pumps are a non-self priming unit built to handle liquid transfer in heating and cooling operations. Typical applications include home heating systems, solar heating systems, heat recovery systems and recirculating water in domestic and commercial hot water tanks. These pumps are not food rated.
• Brewery pump - the March 809 and 815 series of pumps are commonly used by Home Brewers and Breweries.
• Maximum liquid temperature for the 809 and 815 series is 250 F.
• Port configurations include in-line and center inlet with side discharge.
• Construction materials: Bronze, Stainless Steel, Ryton/Polysulfil Plastic. Impellers are Teflon plastic.
• There are many motor options available Including AC, DC and High Speed versions for added flow.
March Pump Mag-Drive Centrifugal Pump Bronze Center Inlet 12VDC High Speed 5.5GPM 3/4"MPT Inlet, 1/2"MPT Outlet
|
499.69 |
|
|
March 809 BRC HS 24VDC Mag-Drive Centrifugal Pumps Bronze 24VDC High Speed 5.5GPM
The March MAGNE-BOOST Hydronic hot water booster pumps are a non-self priming unit built to handle liquid transfer in heating and cooling operations. Typical applications include home heating systems, solar heating systems, heat recovery systems and recirculating water in domestic and commercial hot water tanks. These pumps are not food rated.
• Brewery pump - the March 809 and 815 series of pumps are commonly used by Home Brewers and Breweries.
• Maximum liquid temperature for the 809 and 815 series is 250 F.
• Port configurations include in-line and center inlet with side discharge.
• Construction materials: Bronze, Stainless Steel, Ryton/Polysulfil Plastic. Impellers are Teflon plastic.
• There are many motor options available Including AC, DC and High Speed versions for added flow.
March Pump Mag-Drive Centrifugal Pump Bronze Center Inlet 24VDC High Speed 5.5GPM 3/4"MPT Inlet, 1/2"MPT Outlet
|
501.56 |
|
|
March 809-PL-HS Magnetic Drive Beer Pump
The March 809-PL-HS Home Brew Beer Pump is great for all your brewing needs.
The March 809 PL HS hot water booster pumps are a non-self priming unit built to handle liquid transfer in heating and cooling operations. Typical applications include brewing, home heating systems, solar heating systems, heat recovery systems and recirculating water in domestic and commercial hot water tanks. These pumps are not food rated.
• Home Brewery pump - the March 809 and 815 series of pumps are commonly used by Home Brewers and Breweries.
• Maximum liquid temperature for the 809 and 815 series is 250 F.
• Port configurations include in-line and center inlet with side discharge.
• Construction materials: Bronze, Stainless Steel, Ryton/Polysulfil Plastic. Impellers are Teflon plastic.
• There are many motor options available Including AC, DC and High Speed versions for added flow.
Unit System - 60Hz
Max Flow - 6 GPM - 18.9 LPM
Max Head - 12.1 FT - 2.5 M
Power - .04 HP - .029 KW
Electrical - 115V 60HZ
Type - Centrifugal Mag Drive
Inlet - 1/2"MPT
Outlet - 1/2"MPT
Wet End Polysulfone (Front Housing), Stainless Steel (Rear Housing and Shaft), Teflon (Thrust Washer), Silicone (O-Ring), Ryton/Teflon/Glass (Impeller)
Can handle liquids of 250F Materials and is FDA Food Compliant with 6 Foot Cord and plug Components are UL Recognized.
Made in American
|
348.08 |
|