Gasoline & Propane Sensor Only
This sensor is a replacement for Fireboy-Xintex P systems.
Installation:
The sensor should be located by the propane-powered appliance, near the floor
Avoid areas where damage may take place due to cleaning, mopping, kicking, or other physical damage
Harsh chemicals should not be used to clean sensors
Use the appropriate #8 mounting hardware to mount the Propane Fume Sensor in the desired location
The rubber gasket should be installed between the sensor and the mounting surface
Connect to the extension cable using the attached quick-disconnect connectors (Sold Separately)
|
112.50 |
|
|
Propane & Gasoline Sensor with Cable - Red Plastic Housing
Gasoline & propane sensor with 12" lead and 20' sensor cable.
Compatible With:
G-1 Gasoline Fume Detector
G-2 Gasoline Fume Detector
P-1 Propane Fume Detector
P-2 Propane Fume Detector
*Sold as an Individual
|
148.50 |
|
|
Propane & Gasoline Sensor with Cable - Aluminum Housing
Gasoline & propane sensor with 12" lead and 20' sensor cable.
Compatible With:
G-1 Gasoline Fume Detector
G-2 Gasoline Fume Detector
P-1 Propane Fume Detector
P-2 Propane Fume Detector
*Sold as an Individual
|
163.50 |
|
|
CO Alarm 12/24V DC - Black
A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.
The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream.
The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.
*Long sensor life – approximately 7 year end-of-life (EOL)
Features:
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries
Technical Specifications:
Power Usage - 4 mA
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - No
*Sold as an Individual
|
120.00 |
|
|
CO Alarm Internal Battery - Black
A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.
The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream.
The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.
*Long sensor life – approximately 7 year end-of-life (EOL)
Features:
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install.
Technical Specifications:
Power Usage - None
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - No
*Sold as an Individual
|
120.00 |
|
|
CO Alarm 12/24V DC - White
A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.
The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream.
The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.
*Long sensor life – approximately 7 year end-of-life (EOL)
Features:
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries
Technical Specifications:
Power Usage - 4 mA
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - No
*Sold as an Individual
|
120.00 |
|
|
CO Alarm Internal Battery - White
A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.
The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream.
The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.
*Long sensor life – approximately 7 year end-of-life (EOL)
Features:
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install.
Technical Specifications:
Power Usage - None
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - No
*Sold as an Individual
|
120.00 |
|
|
CO Alarm 12/24V DC with Interconnect - Black
A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.
The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream.
The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.
*Long sensor life – approximately 7 year end-of-life (EOL)
Features:
Interconnect up to ten (10) CO alarms - all connected CO alarms sound together
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries
Technical Specifications:
Power Usage - 4 mA
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - Yes
*Sold as an Individual
|
135.00 |
|
|
CO Alarm Internal Battery w/Interconnect - Black
A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.
The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream.
The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.
*Long sensor life – approximately 7 year end-of-life (EOL)
Features:
Interconnect up to ten (10) CO alarms - all connected CO alarms sound together
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install.
Technical Specifications:
Power Usage - None
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - Yes
*Sold as an Individual
|
135.00 |
|
|
CO Alarm 12/24V DC with Interconnect - Black
A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.
The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream.
The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.
*Long sensor life – approximately 7 year end-of-life (EOL)
Features:
Interconnect up to ten (10) CO alarms - all connected CO alarms sound together
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries
Technical Specifications:
Power Usage - 4 mA
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - Yes
*Sold as an Individual
|
135.00 |
|
|
CO Alarm Internal Battery w/Interconnect - White
A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.
The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream.
The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.
*Long sensor life – approximately 7 year end-of-life (EOL)
Features:
Interconnect up to ten (10) CO alarms - all connected CO alarms sound together
Microprocessor controlled
Compact design for inconspicuous protection
Time-weighted average CO measurement process constantly monitors all CO levels
Highly resistant to most chemicals, solvents & cleaners
CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install.
Technical Specifications:
Power Usage - None
Alarm Point - 10% COHb
Alarm Horn - 85 dBA
Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm)
Interconnect Functionality - Yes
*Sold as an Individual
|
135.00 |
|
|
Fireboy - Xintex
Fireboy-Xintex manufactures top-of-the-line safety devices to keep your boating experience safe. Our equipment detects fires and fatal fumes to protect your marine craft and your life. Fireboy is the world's leading manufacturer of engine compartment fire extinguishing systems.
|
|
|
MA Series Fire Extinguishing System - 450 Cubic Feet
Fireboy-Xintex clean agent fire extinguisher systems are designed to automatically discharge whenever the protected space's ambient temperature reaches 175 degrees Fahrenheit.
When the Fireboy System discharges, the extinguisher is designed to fully empty the HFC-227ea (Heptafluoropropane) and 3M Novec Clean Agent in less than 10 seconds. No clean-up is required. There is no powdery residue or water left behind. The fire is extinguished by a combination of heat reduction and chemical reactions.
*Diesel-powered craft require installation of an Engine Shutdown System
Features:
Protects engine rooms and machinery spaces
Pre-engineered, total flooding system
The safest way to combat an engine room fire
Automatic discharge at 175°F (79°C) with optional manual release
Utilizes HFC-227ea and 3M Novec clean agents – an effective Halon replacement
No water or powdery residue
Includes locking lever for increased safety when removing or installing cable
Certifications:
U.S.C.G.
EN ISO 9094-1 and 9094-2 standards
ISO RINA
MCA Certified
Factory Mutual
Technical Specifications:
Volume Protected - 450 ft3
Dimensions (Dia. x H) - 7.1" x 19.4" (18 x 49.3 cm)
Agent - HFC-227ea and 3M Novec
Agent Weight - 19.4 lbs (8.8 kg)
System Pressure (@70°F) - 240 psi
In the Box:
Fire extinguisher
Mounting bracket
Helm station panel - 90107
Owners manual
*Sold as an Individual
|
1293.75 |
|
|
Gasoline Fume Detector - Black Bezel - 12/24V
The Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate.
Features:
Simple Installation
Audible and visual alarm to indicate LEL (Lower Explosive Level) presence
Monitors one (1) single area
Technical Specifications:
Operating Temperature: -40° to 185°F (-40° to 85°C)
Current Draw Nominal - 55mA
Current Draw Maximum - 95mA
Operating Voltage - 9 to 30V DC
Alarm Horn - 68 dB
Display Style - Round with Black Bezel
Display Dimensions - 2-3/16" (5.6 cm) round
Cutout Dimension - 2-1/16" (5.2 cm) round hole
In the Box:
Fume Detector
Fuel sensors x one (1)
20' Extension Cable x one (1)
Instruction manual
*Sold as an Individual
|
270.00 |
|
|
Gasoline Fume Detector - Chrome Bezel - 12/24V
The Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate.
Features:
Simple Installation
Audible and visual alarm to indicate LEL (Lower Explosive Level) presence
Monitors one (1) single area
Technical Specifications:
Operating Temperature: -40° to 185°F (-40° to 85°C)
Current Draw Nominal - 55mA
Current Draw Maximum - 95mA
Operating Voltage - 9 to 30V DC
Alarm Horn - 68 dB
Display Style - Round with Chrome Bezel
Display Dimensions - 2-3/16" (5.6 cm) round
Cutout Dimension - 2-1/16" (5.2 cm) round hole
In the Box:
Fume Detector
Fuel sensors x one (1)
20' Extension Cable x one (1)
Instruction manual
*Sold as an Individual
|
277.50 |
|